Access Denied!!!

It appears that you are using a private browser which blocks some scripts necessary for this page to function properly. As a result, you may experience limited functionality or the page may not work at all.

To access this page, please consider using a different browser or switch to the standard version of Firefox.

Thank you for your understanding.

Access Full Project

Publicly Funded

Privately Funded

Bidding Soon

Documents Available

Addenda Available

Post-Bid

Post-Bid

Saving Project...

Full details on over 250,000 Projects including 2000 updated daily available to subscribers

October 26, 2023

November 27, 2023

No Information to Display

Multiple Locations

Service, Maintenance and Supply

No Information to Display

No Information to Display

Public - City

img_map_placeholder

Multiple Locations, Springfield, MO

Documents for this project are exclusively Specifications. If Plans become available, we will add them here.

Subscribe to View Full Documents

Transformer, Potential, Abb, 161kv (for Instrumentation) 800/1400:1 Ratio Line Comments See Attachment for Additional Information. A) Type: Outdoor, Oil-filled, Single Bushing, Standard Accuracy, Equal to Kuhlman Ute-170 Series or Approved Equal B) Connection: Line-to-ground on a 161 Kv Line-to-line, 60 Hz Circuit. C) Two (2) Secondary Windings: - X-winding Ratio: 800/1400:1 - Primary Voltage; 92,000 (161 Kv Grounded Y) Volts - Thermal Burden: 3000 Va -accuracy: 0.3zz - Y-winding Ratio: 800/1400:1 - Primary Voltage; 92,000 (161 Kv Grounded Y) Volts - Thermal Burden: 3000 Va -accuracy: 0.3zz - Thermal Burden: 3000 Va D) Bil: 750 Kv E) Light Gray (Ansi 70) Porcelain F) Line Terminal: Aluminum or Tin-plated Bronze 4 Hole Nema Pad. Furnish Cable to Flat Terminal to Bolt Vt Grounding Pad. Ground Terminal: Tinned Bronzed Connector for 2/0 Awg Through 250 Mcm Copper Conductor (Anderson Shw-025b-tn). G) Ansi Relaying and Metering Accuracy Classification 0.3 Class for O, W, X, M, Y, Z, and Zz Burdens. H) Detachable Junction Boxes With 1-1/2 Inch Conduit Entrance With Removable Weather Tight Plugs. I) Neutral Bushing Externally Connected to Ground. J) Weight: Approx. 770 Lbs. K) Oil Capacity: Approx. 25 Gals., Certified Non-pcb the 161 Kv Voltage Transformers (Vt's) Will Be Used in a Retrofit Application to Replace Existing Coupling Capacitor Voltage Transformers (Ccvt's) Weighing Approximately 725 Lbs. Design Intent is Reuse the Existing Ccvt Steel Supports Stands to Support the New Vt's, So Matching Design Specs (Including Dimensions, Weight, and Mounting Holes) Are Critical in Evaluation of the New Vt's. Please Provide Hard Copies, and All Applicable Pdf & Cad Drawings, Manuals, Etc.

2 Record(s)

Subscribe to Get All Contact Details

Trades

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet
Subscribe to See All Trade Details

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

Related Projects