Access Denied!!!

It appears that you are using a private browser which blocks some scripts necessary for this page to function properly. As a result, you may experience limited functionality or the page may not work at all.

To access this page, please consider using a different browser or switch to the standard version of Firefox.

Thank you for your understanding.

Access Full Project

Publicly Funded

Privately Funded

Bidding Soon

Documents Available

Addenda Available

Post-Bid

Post-Bid

Saving Project...

Full details on over 250,000 Projects including 2000 updated daily available to subscribers

September 5, 2024

October 7, 2024

September 3, 2026

398 E Panther Ave

Renovation

No Information to Display

$39,000,000.00

Public - City

img_map_placeholder

398 E Panther Ave, Jal, NM

145

34

81

4

Subscribe to View Full Documents

Jal Public Schools will receive Competitive Sealed Proposals for General Construction Work for the Jal Indoor Athletic Field project, located at 398 East Panther, Jal, New Mexico 88252. SCOPE/APPLICATION A. Provide installed firestop protects that limit the spread of fire, heat, smoke, and gasses through otherwise unprotected openings in rated assemblies, including walls, partitions, floors, roof/ceilings, and similar locations restoring the integrity of the fire rated construction to its original fire rating. B. Provide firestop systems listed for the specific combination of fire rated construction, type of penetrating item, annular space requirements, and fire rating, and the following criteria: 1. F-Rating: Equal to or greater than the fire-resistance rating of the assembly in which the firestopping will be installed. 2. T-Rating: In habitable areas where penetrating items are exposed to potential contact with materials on fire side(s) of rated assembly, T-rating must equal its F rating. 3. L-Rating: L-rating of 1 cfm per linear foot maximum at ambient temperatures. 4. Wall Penetrations: Systems must be symmetrical, with the same rating from both sides of the wall. 5. Testing: Determine ratings in accordance with ASTM E814 or UL 1479. C. Provide firestopping systems listed for construction gaps per the specific combination of fire-rated construction type, configuration, gap dimensions, and fire rating, and the following criteria: 1. Fire resistance rating must be equal to or greater than that of the assembly in which it is to be installed. 2. Movement capability must be appropriate to the potential movement of the gap, demonstrated by testing in accordance with ASTM E1399 for minimum of 500 cycles at 10 cycles per minute. 3. L-Rating: L-rating of 1 cfm per linear foot maximum.

23 Record(s)

Subscribe to Get All Contact Details

Trades

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet
Subscribe to See All Trade Details

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.