Access Denied!!!

It appears that you are using a private browser which blocks some scripts necessary for this page to function properly. As a result, you may experience limited functionality or the page may not work at all.

To access this page, please consider using a different browser or switch to the standard version of Firefox.

Thank you for your understanding.

Access Full Project

Publicly Funded

Privately Funded

Bidding Soon

Documents Available

Addenda Available

Post-Bid

Post-Bid

Saving Project...

Full details on over 250,000 Projects including 2000 updated daily available to subscribers

October 6, 2023

November 6, 2023

No Information to Display

To Be Determined

Renovation

No Information to Display

$23,924.00

Public - City

img_map_placeholder

To Be Determined, Robinson, IL

Plans and Specifications are not available for this project. If that changes, they will be made available here.

Subscribe to View Full Documents

The City of Robinson, IL Wastewater Treatment Facility (WWTF) is now accepting bids for a new Control Panel for Smith Lift Station. The unit shall contain the necessary equipment and appurtenances as per the specifications. Bids should include freight and cost of Instillation. Questions concerning the bid specifications should be directed to Mr. Dylan Dart, Superintendent of the Wastewater Treatment Facility, 1000 N. Mitchell Ave., Robinson, IL 62454. Telephone (618) 553-1180. The City of Robinson reserves its right to accept the bid which it believes to be in its best interest, waive any formalities, and to reject any and all bids. ONE (1) - PRIMEX Custom Duplex Control Panel, for operation on 240 Volt 3 Phase 4 wire Service, to control 2 -10 HP FLYGT pumps, with a FLA of 26 amps. Panel will include the following: NEMA Type 3R Steel enclosure - 42" X 30" X 12", Wall Mount Enclosure Aluminum Dead Front Inner door, with Latch Strip Enclosure Heater Incoming Power Terminal Block Phase/Voltage Monitor with Input Fusing Incoming Power Lighting Arrestor Control Power Circuit Breaker Control Power Fuse Two Pump Circuit Breaker rated for 10 HP Two NEMA Motor Starters Rated at 10 HP Alternating Relay with Lead-Lag Switch Time Delay Relay for the Lag Pump 5 Channel SYMCOM Intrinsically Safe Relay 22 MM Hand-Off-Automatic Pump Selector Switch Elapsed Running Time Meters - Pump 1, Pump 2, Both Pumps Running 22 MM Pump Fail Pilot Lights, With Manual Reset Pushbuttons, and Alarms LED High Level Alarm Light Audible Alarm Horn, with 22 MM Silence Pushbutton 15 Amp GFI Convenience outlet 6" X 6" Space for Field Mounting of Customer I.S. Barrier (Customer Supplied) 120 Volt to 24 Volt Transformer for Float Switches Engraved Nameplates Self- Laminating Wire Markers Control Relays, as required Terminal Blocks and Ground Lugs as required UL Label 698 FOUR (4) - MJK Float Switches 7030, with External Weight and 65' cables ONE (1) - Stainless Steel Cable Holder, with Stainless Steel Anchors ONE (1) LOT - Electrical Installation Materials ONE (1) LOT - Field Service Labor, at Prevailing Wages, to assist the Controls Group Technician with Hoisting and Installation Assistance for the Duration of the Project ONE (1) LOT - Controls Group Labor, at Prevailing Wages, to Install the Items listed In the Proposal above, Provide Termination of all Electrical Components, and Test the Operation of the System once the Installation has been Completed Freight will be Included in the bid

3 Record(s)

Subscribe to Get All Contact Details

Trades

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet
Subscribe to See All Trade Details

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.