Access Denied!!!

It appears that you are using a private browser which blocks some scripts necessary for this page to function properly. As a result, you may experience limited functionality or the page may not work at all.

To access this page, please consider using a different browser or switch to the standard version of Firefox.

Thank you for your understanding.

Access Full Project

Publicly Funded

Privately Funded

Bidding Soon

Documents Available

Addenda Available

Post-Bid

Post-Bid

Saving Project...

Full details on over 250,000 Projects including 2000 updated daily available to subscribers

October 25, 2023

November 27, 2023

No Information to Display

To Be Determined

Renovation

No Information to Display

$500,000.00

Public - County

img_map_placeholder

To Be Determined, Richmond, IN

Plans and Specifications are not available for this project. If that changes, they will be made available here.

Subscribe to View Full Documents

The project will consist of the complete removal of (2) underground tanks and the Closure of (1) Underground Tank. The installation of 3 new above ground storage tanks including fueling stations, supplies, labor and compliance of IDEM/EPA regulations Removal Activities The project consists of the complete removal of (2) underground fuel tanks (1) 12,000 gallon diesel, (1) 12,000 gallon unleaded fuel tank and associate equipment and piping. The closure in place of (1) 1,000 gallon diesel generator tank and all required IDEM sampling, analysis, and closure reporting. A certified UST removal contractor must be utilized. Once tanks are removed, the tank void must be filled with compacted stone. All IDEM/EPA rules for removal and closure-in-place must be followed. o IDEM 30-day notice of intent to close filing for removal of (2) 12,000 gallon UST's o IDEM 30-day notice of intent to close in place for (1) 1,000 gallon generator UST o Excavate and remove (1) 12,000 gallon diesel UST and (1) 12,000 gallon unleaded UST o Clean UST and transport for proper tank disposal o Saw cut, excavate and remove tank equipment on (1) 1,000 gallon diesel generator UST. o Clean 1,000 gallon UST and fill with flowable fill for closure in place o IDEM required sampling o Soil samples for VOCs, PAHs, and lead analysis from excavation base, sidewalls, backfill (assumes less than 50 CY of soil excavated), pipe run, two (2) dispensers and ground water sample from each of the UST excavations. o IDEM required sample analysis and closure report o Removal and disposal of all contaminated soil o Removal and disposal of dispensers o Removal and disposal of dispensers Installation Activities o Obtain Indiana State Fire Marshal Construction Design Release (CDR) o Supply and install the following aboveground storage tanks o (1) Highland Tank 12,000-gallon UL142 double-wall tank for diesel (or approved equal) o (1) Highland Tank 12,000-gallon double-wall UL2085 Fireguard tank for unleaded (or approved equal) o (1) Highland Tank 1,000-gallon UL142 double-wall tank for generator (or approved equal) o Supply and install the following tank equipment on diesel 12,000-gallon tank o (1) Franklin Fueling FE Petro 2hp submersible pumps with pump controller(or approved equal) o (2) Morrison Emergency vents (or approved equal) o (1) Morrison atmospheric vents (or approved equal) o (1) Morrison 818 clock gauge (or approved equal) o (1) Morrison 78DI expansion relief (or approved equal) o (1) Morrison 710 1 1/2 " solenoid valve for anti-siphon (or approved equal) o Supply and install the following tank equipment on unleaded 12,000-gallon tank o (1) Franklin Fueling FE Petro 1 1/2 hp submersible pumps with pump controller (or approved equal) o (2) Morrison emergency vents (or approved equal) o (1) Morrison atmospheric vents (or approved equal) o (1) Morrison 818 clock gauge (or approved equal) o (1) Morrison 78DI expansion relief(or approved equal) o (1) Morrison 710 1 1/2 " solenoid valve for anti-siphon (or approved equal) o Supply and install (1) Morrison 515-0300 (3") remote fill for diesel located on tank pad(or approved equal) o Installation of 3" remote fill piping Morrison 3" check valve (or approved equal) Morrison 3" ball valve (or approved equal) 3" cap and adapter o Supply and install (1) Morrison 515-2300 (3" x 3") remote fill for unleaded located on tank pad (or approved equal) o Installation of 3" remote fill piping and 3" vapor recovery piping Morrison 3" check valve (or approved equal) Morrison 3" ball valve (or approved equal) (2) 3" cap and adapters (product/vapor recovery) o Supply and install aboveground unleaded fuel piping from fuel tank to tank pad mounted unleaded dispenser o Perform excavation for diesel piping from tank pad to (2) separate fuel islands o Supply and install Franklin Fueling XP-150-SC 1 1/2 " double-wall fuel piping from tank to each diesel dispenser (or approved equal) o Supply and install all required entry boots and termination fittings on fuel pipe o Supply and install (2) 4' x 12' concrete fuel islands with steel island forms painted yellow o Supply and install (3) Franklin Fueling LMM-2313 polyethylene dispenser sumps at fuel islands (or approved equal) o Supply and install (2) Bennett Pump Co. model 3712SNR remote electronic fuel dispensers for diesel (or approved equal) o Single product/2-hose outlets o Volume only o Includes nozzles, hoses, breakaways, whip hose and swivels o Supply and install (1) Bennett Pump Co model 3711SNR-17 remote electronic fuel dispenser for unleaded on first island from tank (or approved equal) o Single product/single hose outlet o Volume only o Includes nozzles, hoses, breakaways, whip hose and swivel o Supply and install (2) Tecalemit 500 gallon All-In-One DEF Island unit (or approved equal) o Heated and insulated o Pulse output (required for fuel control integration) o 25' DEF hose and reel o Supply and install Fuel Force 814 fuel control system (or approved equal) o Single master with (2) remotes (One on unleaded tank pad, one at each of 2 diesel dispenser islands) o FuelServe.net cloud based fuel control o Wireless modem, first year cell modem service included o Supply and install (1) Franklin Fueling EVO400 Fuel Management/Leak Detection Systems (or approved equal) o (3) FMP-LL3 digital inventory only probes with float kits o (3) FMP-ULS interstitial sensor o (3) FMP-ULS dispenser sump sensors o (3) FMP-ULS transition sump sensors o Overfill alarm with acknowledgement o Installation of required electrical for fuel system, leak detection system and fuel control system Options to be priced separately: o Supply and install the following tank pads A. (1) 30' x 31' x 12" tank pad for diesel and unleaded tanks B. Installation of 4" concrete filled bollards around tank pad perimeter option A C. (1) 13' 20' x 12" tank pad for diesel generator tank D. Installation of 4" concrete filled bollards around tank perimeter option C Each bid shall be accompanied by a surety bond or certified check in favor of the Board of Commissioners of Wayne County, Indiana, in a sum of not less than ten per cent (10%) of the amount of the bid, and shall in all respects conform to the laws governing such matters. Bidder to state date of delivery F.O.B. to the Wayne County Highway Garage, Centerville, Indiana 47330. The Board of Commissioners reserves the right to reject any and all bids.

1 Record(s)

Subscribe to Get All Contact Details

Trades

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet
Subscribe to See All Trade Details

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

Related Projects