Access Denied!!!

It appears that you are using a private browser which blocks some scripts necessary for this page to function properly. As a result, you may experience limited functionality or the page may not work at all.

To access this page, please consider using a different browser or switch to the standard version of Firefox.

Thank you for your understanding.

Access Full Project

Publicly Funded

Privately Funded

Bidding Soon

Documents Available

Addenda Available

Post-Bid

Post-Bid

Saving Project...

Full details on over 250,000 Projects including 2000 updated daily available to subscribers

November 2, 2023

January 1, 2024

December 19, 2024

Multiple Locations

Renovation

No Information to Display

$1,200,000.00

Public - County

img_map_placeholder

Multiple Locations, Jacksonville, NC

Subscribe to View Full Documents

The right is reserved to reject any or all bids, to waive informalities. Bidders are notified that legislative acts relating to licensing of contractors will be observed in receiving bids and awarding contracts and that satisfactory performance and payment bonds will be required on this project. Work of the Project includes, but is not limited to: 1. Installation of a packaged booster pumping system, including pumps, piping, and valving, with integrated variable frequency drives (VFD) and construction of an elevated booster pump station building. 2. 10-inch water main piping connecting to the existing 10-inch water main on Island Drive (NC 210) by open-cut installation. 3. Electrical service, wiring, conduits, and connections to the pump control system. 4. Water main piping connections to a skid-mounted booster pump system, valves, fittings, and appurtenances. 5. Installation of a 10-inch check valve and vault at the proposed booster pump station site. 6. Installation of a 10-inch electric actuated butterfly valve and vault at the proposed booster pump station site. The electric-actuated butterfly valve shall be remotely operable through SCADA. 7. Monorail hoist installed inside the pump station building. 8. Installation of a 12-inch check valve, vault, and bypass piping connection on the existing 12-inch water main crossing the Intracoastal Water Way at Marina Way. 9. Installation of two (2) 12-inch electric actuated gate valves at the Marina Way site that shall be remotely operable through SCADA. 10. Other work associated with the construction of the booster pumping station, as shown on the construction plans.

18 Record(s)

Subscribe to Get All Contact Details

Trades

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet
Subscribe to See All Trade Details

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

Related Projects