Access Denied!!!

It appears that you are using a private browser which blocks some scripts necessary for this page to function properly. As a result, you may experience limited functionality or the page may not work at all.

To access this page, please consider using a different browser or switch to the standard version of Firefox.

Thank you for your understanding.

Access Full Project

Publicly Funded

Privately Funded

Bidding Soon

Documents Available

Addenda Available

Post-Bid

Post-Bid

Saving Project...

Full details on over 250,000 Projects including 2000 updated daily available to subscribers

August 16, 2023

September 15, 2023

December 14, 2023

2630 Morningside Dr

Renovation

No Information to Display

$247,780.00

Public - County

img_map_placeholder

2630 Morningside Dr, Tyler, TX

Subscribe to View Full Documents

As of August 21, 2023 , this project has not yet been awarded. The project is expected to be awarded either on the 8/29/2023 or 9/5/2023 Smith County reserves the right to award by unit cost or lump sum discount and waive any irregularities or formalities in the best interest of Smith County. Smith County reserves the right to reject any or all bids/proposals or to waive any informalities. In general, the scope of work includes spot repair to the areas distressed EIFS/stucco, crack repair, and the application of a compatible elastomeric wall coating and new sealant joints across the existing cladding. Specific bid items are listed below. Engineer estimate is $350,000. Spot repair the areas of distressed EIFS/stucco & tie-in to existing. Rout out and seal cracks in one coat stucco as required, prior to applying new elastomeric wall coating. 2. Apply compatible elastomeric wall coating (Masterprotect EL 750 or equal) and new sealant joints across the existing EIFS cladding. Applying a new elastomeric wall coating and sealant joints will seal up the EIFS and restore the weather performance of the barrier system for the time being; until removal and replacement of the EIFS cladding can be performed at a later time. 3. Remove and replace deteriorated sealant joints at the split-faced CMU exterior walls. 4. Remove and replace deteriorated sealant joints at the exterior wall-to-paving interfaces. 5. Remove and replace the fogged/hazed window like and kind at office 1035. 6. Remove and reset windowsto repair/adjust sill pansthat are negatively sloped toward building. 7. Seal the gaps/separations at glazing gasket corners, asrequired

12 Record(s)

Subscribe to Get All Contact Details

Trades

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet
Subscribe to See All Trade Details

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.