Access Denied!!!

It appears that you are using a private browser which blocks some scripts necessary for this page to function properly. As a result, you may experience limited functionality or the page may not work at all.

To access this page, please consider using a different browser or switch to the standard version of Firefox.

Thank you for your understanding.

Access Full Project

Publicly Funded

Privately Funded

Bidding Soon

Documents Available

Addenda Available

Post-Bid

Post-Bid

Saving Project...

Full details on over 250,000 Projects including 2000 updated daily available to subscribers

August 3, 2023

October 1, 2023

September 30, 2024

To Be Determined

Demolition, New Construction, Site Work

No Information to Display

$7,875.00

Public - County

img_map_placeholder

To Be Determined, Decatur, TX

Documents for this project are exclusively Specifications. If Plans become available, we will add them here.

Subscribe to View Full Documents

Asphalt Road Surfacing Materials Bridge Building & Reconstruction Bulk Fuel- Gasoline & Diesel Concrete Culverts Landfill Transfer Station Magnesium Chloride Pile Driving Road Oils, Asphalt, & Liquids Rock & Base Materials Sale of Scrap Iron Wise County reserves the right to accept and/or reject any and all bids for any reason whatsoever Written requests shall be emailed to: Diana Allen at Diana.allen@co.wise.tx.us. 1. Deck: Reinforced 7-1/2 inch thick concrete deck, as detailed in Attachment A. The concrete for the slab shall be Class S with minimum 28-day compressive strength of 4,000 PSI. The reinforcing steel shall be grade 40. Testing shall be provided by the contractor. The deck should be secured to the beams with stud connectors at 4-foot centers, as detailed in Attachment B, for compression flange bracing, and to ensure that the deck does not shift laterally. In lieu of studs, 7-inch channel-section connectors may be used. 2. Beams: Wide flange W 36 x 130 Beams at 5-foot centers. The beams should be interconnected with end diaphragms over each abutment and with interior diaphragms at the mid-span, as shown in Attachment B. However, the interior diaphragm detail should be moved up as close to the place of the compression (top) flange as practical (clear the radius) to provide additional torsional bracing. Also, the vertical stiffeners should be extended to attach to the top flange. Bridge Building and Reconstruction 3. Header Walls: Header walls will be constructed of 1/4 -inch plate welded to the outside of the 24-foot abutment and extended at least 10 feet at 45-degree angles to the approach roadway. The sideslope shall be 3:1, and 2:1 slope underneath the bridge. The abutment and header walls shall be backfilled with 2- sack flowable concrete that conforms to TXDOT specification Item 401. Flowable Backfill. 4. Metal Beam Guard Fence(MBGF): Metal Beam Guard Fence shall be installed in accordance with the associated TXDOT standard sheets *The list of planholders and/or interested bidders is not being tracked by the stakeholders involved with this project. If you are an interested contractor and wish to be listed as a bidder, please notify our editorial staff at addtobidlist@constructconnect.com. Bid Results : Price Per Linear Foot : Horton Bridge and Piling - $1,975.00 Price Per Linear Foot w/Materials : Horton Bridge and Piling - $5,900.00

3 Record(s)

Subscribe to Get All Contact Details

Trades

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet
Subscribe to See All Trade Details

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

Related Projects