Access Denied!!!

It appears that you are using a private browser which blocks some scripts necessary for this page to function properly. As a result, you may experience limited functionality or the page may not work at all.

To access this page, please consider using a different browser or switch to the standard version of Firefox.

Thank you for your understanding.

Access Full Project

Publicly Funded

Privately Funded

Bidding Soon

Documents Available

Addenda Available

Post-Bid

Post-Bid

Saving Project...

Full details on over 250,000 Projects including 2000 updated daily available to subscribers

October 23, 2023

November 22, 2023

May 20, 2024

4004 Arkona Rd

Renovation

No Information to Display

$80,000.00

Public - Federal

img_map_placeholder

4004 Arkona Rd, Milan, MI

Documents for this project are exclusively Specifications. If Plans become available, we will add them here.

Subscribe to View Full Documents

The selected contractor shall provide all materials, labor, and equipment for the project titled Replace Transformer & Load Break at the Federal Correctional Complex (FCI) Milan located in Milan, Michigan in accordance with the attached Statement of Work and Drawings. All work shall be completed per NEC 2020, NESC, and Bureau of Prison Technical Design Guidelines. o All equipment and wire shall be at least 15 KV rated. o All conduit besides underground shall be RMC with watertight fittings o All conductors shall be copper o Fuses: Provide six of each type and rating used. Include spares for fusible devices. Fuses shall match type installed and be packaged with protective covering for storage and identified with labels describing contents. o Provide a strip heater in each switch and switchgear, and a dedicated power circuit for the heater. o The medium voltage switches shall be manually operated and rated at 600-to-1200-amp continuous load break with required fault ratings. The switch mechanism shall provide quick closing and opening independent of the handle speed. The switch shall be cable connected to the transformer to prevent sound transmission to the switch. o Three (3) current limiting fuses are to be provided on the load side of the medium voltage switch in the medium voltage switch compartment. Provide the following interlocking capabilities: -The hinged access door shall be interlocked with the switch to prevent closing of the switch until the door is closed. -Key interlock the access to the fuse such that both switches must be opened before fuses can be accessed. -The following accessories are to be provided: -Terminal compartment. -Lightning arrestor. -Interlocks. -Potheads/Clamp terminals. Deadline 10/04/2023 at 12:00 PM ET 15B41723Q00000029

4 Record(s)

Subscribe to Get All Contact Details

Trades

Division 00 - Lorem Ipsum

Division 00 - Lorem Ipsum

Lorem, Ipsum, Dolor, Sit amet
Subscribe to See All Trade Details

You’ve Reached the Free View Limit

Want to see more project and bidder data in your market? Check out our product options and see what works best for you and your business.

Come back in [[refresh_days]] to get [[project_count]] more free projects.

Related Projects